What we provide
Air duct inspection
A camera survey shows the real condition of the ductwork from the inside — the thickness of settled dust, grease, corrosion, leaking joints and even building debris left inside during construction. The recording becomes the basis for deciding whether one branch needs cleaning or the whole system does.
- Survey before cleaning and a check recording once it is finished
- Video or photo documentation as evidence of the duct condition
- Assessment of access hatches and a proposal for where to add them
- Regular diagnostics as a basis for a maintenance plan
Deep cleaning and disinfection of ductwork
Ducts are cleaned mechanically with rotary brushes and heads, and the loosened dirt is extracted as the work proceeds so that dust does not reach the room. In most cases the ductwork does not need to be dismantled, and the equipment reaches the less accessible corners and branches as well.
- Supply and extract ventilation and air conditioning ductwork
- Process dust extraction and heat removal from production
- Greasy and oily extraction ducts from kitchens and hoods
- Risers and shared ductwork in apartment buildings
- Areas with higher cleanliness requirements — food production, healthcare, clean rooms
Once cleaned, the surfaces can be treated with a disinfectant against bacteria, viruses and mould. A record of the work carried out is part of the delivery. After cleaning we also recommend replacing the filters in the air handling unit.
Cleaning at height
Duct cleaning is often carried out at height and from platforms — the same way, we can clean the other surfaces under the roof of a hall that routine maintenance cannot reach.
- Walls, beams and structures, surfaces of installations inside halls
- Outer surfaces of ventilation ductwork
- Skylights, lighting and luminaires
- Crane runways
- Pipework for utilities — water, gas, electrical routes, compressed air, vacuum
Cleaning in potentially explosive (ATEX) areas
In areas where combustible dust settles or flammable gases and vapours occur, cleaning is carried out under special conditions. The dust layer is also the main reason why cleaning cannot be postponed: under Slovak Ministry of the Interior Decree No. 79/2004 (Section 2), a continuous layer of combustible dust 1 mm thick or more is considered capable of spreading fire.
- Work in areas classified as potentially explosive atmospheres
- Dust extraction and collection without stirring it up into the room
- A procedure matched to the explosion protection document of the specific site
Vacuum system servicing
Vacuum lines and equipment lose performance gradually — fouled pipework, leaks and dirty filters show up as a drop in vacuum level well before an actual failure.
- Cleaning of vacuum lines and collection vessels
- Checking the vacuum level and tracing leaks
- Regular servicing and replacement of filters and consumable parts
Why cleaning pays off
- Health and comfort — settled dust holds bacteria, mould and dust mites that are carried into the air of the room. They can aggravate asthma, allergies and other respiratory problems.
- Fire prevention — a layer of combustible dust, like grease in kitchen extraction ducts, is combustible material along the whole length of the duct.
- Running costs — fouled ducts and filters that clog faster increase pressure loss and fan consumption.
- Process performance — a restricted cross-section reduces the efficiency of process extraction; in extreme cases the duct stops doing its job.
- Production cleanliness — in food production and clean rooms, contamination from the ductwork is a direct risk.
How the work proceeds
- Duct survey — a camera record of the ductwork and a cleaning plan.
- Cleaning — mechanical cleaning with rotary brushes and continuous extraction, to a scope based on the type of soiling.
- Disinfection — application of a disinfectant to the cleaned surfaces, where required.
- Completion — a check recording and a report that serves as the starting point for the next cleaning cycle.
Recommended intervals
| Ductwork | Indicative interval | What to consider |
|---|---|---|
| Air conditioning and ventilation ductwork | every 1.5–2 years | We recommend replacing the unit filters after cleaning |
| Greasy and oily kitchen extraction ducts | roughly every 6 months | Grease is combustible — the interval depends on how busy the kitchen is |
| Process dust extraction | based on the site and dust volume | Watch the thickness of the settled layer and any drop in flow |
| New or refurbished building | before being put into service | Building dust and debris get into the ductwork during construction work |
The intervals are indicative — a camera survey and the nature of the site will determine them more precisely. We are happy to help you prepare a maintenance plan.
Air conditioning units, their installation and servicing are covered under air conditioning; heating and hot water are handled by heat pumps.